High Quality Metal Housing Dental Ultrasonic Scaler, Bestseller Metal Housing Dental Magneto Scaler, Best Magneto Scaler for Dentistry Suppliers in China

Home > Products > Metal Implanted Machine > Dental Scaling Machine Metal Housing

Dental Scaling Machine Metal Housing

Dental Scaling Machine Metal Housing

    Packaging: By paper box
    Productivity: 200 units / month
    Brand: ELiTEDENT
    Transportation: Ocean,Air,Express
    Place of Origin: Taiwan
    Supply Ability: 200 units / month
    HS Code: 9018
    Port: Port of Keelung

Basic Info

Model No.: MS-1

Product Description

Rolence® ELiTEDENT® MS-1 Ultrasonic Scaler:

Multi-voltage 110V/230V

Dimension:

Height: 6.5 cm

Width: 23.0 cm

Depth: 22.0 cm

Weight: 2.1 kg


Rolence Enterprise Inc. is an ISO 13485 certified manufacturer of Ultrasonic Scaler. All the products are FDA registered and compliant with EN standard (CE Marking).

Conformance to Standards:

The Rolence® ELiTEDENT® MS-1 Ultrasonic Scaler conforms to IEC60601-1-2:2001 and IEC60601-1-1:2000. The device is CE marked corresponding to European Medical Device Directive (93/42/EEC)

Supplies and Replacement Parts

Contact your local Rolence dealer to order supplies or replacement parts. There are no serviceable parts included in this device. Please contact your dealer to acquire all repairing service and technique supports.

Caution: Equipment not suitable for use in the presence of flammable anesthetic mixture with air or with nitrous oxide.

Caution: US federal law restricts this device to sale by or on the order of a dental professional.

Ultrasonic procedure

1. All general supra and subgingival scaling applications.

2. Periodontal debridement for all types of periodontal diseases.


Contraindications

1. Ultrasonic Systems should not be used for restorative dental procedures involving the condensation of amalgam.

2. This device is designed to work with all Cavitron® (remark) insert with 25 kHz or 30 kHz frequency automatically. For optimum performance please use only qualified inserts supplied by Cavitron® or Rolence®.

3. Do not use the Ultrasonic Scaler if the patient or operator is wearing a pacemaker.

Remark: Cavitron® is a registered trademark of Dentsply® International, Inc.

Warnings

1. Persons who are fitted with cardiac pacemakers, defibrillators and other active implanted medical devices, have been cautioned that some types of electronic equipment might interfere with the operation of the device. We recommend that the MS handpiece cable kept at least 6 to 9 inches (15 to 23 cm) away from any device and their leads during use.

2. During using the unit, make sure that water is flowing continuously. If the handpiece overheats please check the water supply, and stop using the Ultrasonic Scaler for a while.

General Information

If the installation of your ELiTEDENT® Ultrasonic Scaler is performed by someone other than trained Rolence distributor personnel, care should be taken to observe the following requirements and recommendations.

Unpacking the System

Carefully unpack your ELiTEDENT® Ultrasonic Scaler and verify that all components and accessories are included:

1. ELiTEDENT® Ultrasonic Scaler main unit with factory installed water supply line and MS handpiece cable set.

2. Power Cord

3. Foot Pedal.

4. User Manual.

5. Ultrasonic Inserts (Optional).

System Installation

1. The ELiTEDENT® Ultrasonic Scaler MS-1 is designed for both horizontal and vertical placement on a level surface. Refer to section 7.6 for more information of vertical installation.

2. Be sure unit is stable and resting on four feet.

3. Placing unit in direct sunlight may discolor plastic housing.

Techniques for Use of Ultrasonic Scaler

Patient Positioning

1. For optimal access to both the upper and lower arches, the backrest of the chair should be adjusted to a 45° degree angle. This assures patient comfort and clinician visibility.

2. Have the patient turn his/her head to the right or left. Also position chin up or down depending upon the quadrant and surface being treated. Evacuate irrigate using either a saliva ejector or High Volume Evacuator (HVE).

Performing Ultrasonic Scaling

Procedures

Note: Refer to the Infection Control Information Booklet supplied with your system for general procedures to be followed at the beginning of each day and between patients.

1. The edges of ultrasonic inserts are intentionally rounded so there is little danger of tissue laceration with proper ultrasonic scaling technique. Whenever the insert tip is placed in the patient’s Mouth, the lips, check and tongue should be retracted to prevent Accidental prolonged contact with the activated tip.

2. Hold the empty handpiece in an upright position. Activate the Foot Control until fluid exits.

3. Lubricate the rubber O-ring on the insert with water before placing it into the handpiece. Fully set the insert in with a gentle push-twist motion. DO NOT FORCE IT INTO PLACE.

4. Activate the Ultrasonic Scaler. Hold the handpiece over a sink or drain. Check spray temperature to verify fluid is reaching the working end of the insert tip. Adjust the water cooler irrigate. Control knob to ensure adequate flow for the selected Power setting. Greater flow settings provide cooler irrigation.

5. It may be necessary to adjust water flow larger under "Turbo" mode (Foot pedal fully depressed) so adequate fluid will be available to cool tip and tooth interface.

6. In general, it is suggested a "feather-light-touch" be used both supra and subgingivally. The motion of the activated tip and acoustic effects of the irrigating fluid, in most cases, is adequate to remove even the most tenacious calculus.

7. Periodically check the ultrasonic insert for wear with the Insert Efficiency Indicator.

8. The use of a saliva ejector or High Volume Evacuator (HVE) is recommended during all procedures.

9. Set the System's Power Adjustment knob to the lowest power setting for the application and the selected insert.

10. If water leakage is found in handpiece, replace the sleeve or o-ring on MS handpiece cable set assembly to eliminate.

Rolence Enterprise Inc.

  • 1
  • 2
  • 3
  • 4
 

Rolence Enterprise Inc. headquartered in Taiwan, develops, manufacturing & innovation on small equipment of Ultrasonic Scaler, Portable X-Ray, Dental Digital Sensor and LED Curing Light...etc. For over 40 years, we are an international supplier of dental equipment for various companies .


Multi-innovative developments & processes, proven know-how and high-quality have given us a leading position to our customer. and keep up with the innovative and creative design concepts into our products chain by incorporating the dentists` and other technology industry needs.


Besides, with further office locations will be in Germany, we will keep expending our office establish in different country afterward, and supporting our customer latest information, product training, and marking media to increase your business, that`s why we are approaching you to present ourselves & the products to reach a good cooperation in the future.

Company Info

  • Company Name: Rolence Enterprise Inc.
  • Representative: Sterling Cheng
  • Product/Service: Portable X-Ray , Curing Light , Ultrasonic Scaler , Curing Box , Dental Digital Sensor , UV Spot Curing
  • Capital (Million US $): TWD$65,400,000
  • Year Established: 1981
  • Total Annual Sales Volume (Million US $): US$2.5 Million - US$5 Million
  • Export Percentage: 81% - 90%
  • Total Annual Purchase Volume (Million US $): US$1 Million - US$2.5 Million
  • No. of Production Lines: 3
  • No. of R&D Staff: 5 -10 People
  • No. of QC Staff: Fewer than 5 People
  • OEM Services Provided: yes
  • Factory Size (Sq.meters): Below 1,000 square meters
  • Factory Location: No. 18-3 , Lane 231, Pu Chung Rd., Chungli Dist., Taoyuan City, Taiwan R.O.C. 32083
  • Contact Person: Mr. Peter Chiu
  • Tel: +886-3-4631999
Email to this supplier
  • *Subject:
  • To:

  • *Messages:
    Your message must be between 20-8000 characters